蜜桃免费在线视频,蜜桃视频中文字幕,蜜桃成人高清在线观看,蜜桃成人在线无码在线观看

    歡迎進入山東蜜桃免费在线视频環保能源設備有限公司

    熱線電話

    0531-69953988

    分類導航
    產品展示
    聯係蜜桃免费在线视频
    山東蜜桃免费在线视频環保能源設備有限公司

    聯係電話:18678860671

    服務熱線:0531-69953988

    聯係地址:中國(山東)自由貿易試驗區濟南片區孫村街道經十東路33688號章錦綜合保稅區聯東U穀科創中心5號樓 101

    蜜桃视频中文字幕生物脫硫係統的調試過程

    蜜桃视频中文字幕生物脫硫係統,采用生物滴濾技術。生物滴濾塔反應器可以采用PP-H板(均聚聚丙烯)、玻璃鋼或其它耐腐蝕材料的塔體製成,塔體具有防紫外功能,整體整潔、美觀。脫硫的撬裝設備間內,整合了所有的自控係統。填料采用PP材質製作,大量的填料用於向微生物細菌生產繁殖提供足夠的表麵空間。

    Biodesulfurization system of biogas adopts biological trickling filtration technology. The bio trickling filter reactor can be made of PP-H plate (homopolymer polypropylene), glass fiber reinforced plastic or other corrosion-resistant materials. The tower body has the function of ultraviolet protection and is clean and beautiful. All automatic control systems are integrated in the skid mounted equipment room for desulfurization. The filler is made of PP material, and a large number of fillers are used to provide sufficient surface space for the production and reproduction of microbial bacteria.
    Environtec將會在一次啟動調試時提供細菌接種包,包括硫杆菌屬和絲硫菌屬。蜜桃视频中文字幕經由內部進氣管上進下出,塔體設計的一般大正壓為50mbar,一般大負壓為-5mbar。
    Environtec will provide a bacterial inoculation package during the first startup and commissioning, including Thiobacillus and Thiobacillus. The biogas enters and exits from the top to the bottom through the internal intake pipe. The general large positive pressure of the tower body design is 50 mbar, and the general large negative pressure is - 5 mbar.
    用戶方應盡量避免塔體產生超壓或負壓現象,以防止潛在的塔體損壞風險。本項目在塔頂設計有專用的超壓負壓保護裝置。
    The user shall avoid overpressure or negative pressure on the tower body as much as possible to prevent potential tower body damage risk. In this project, a special overpressure and negative pressure protection device is designed on the tower top.
    為達到設計的脫硫目標,微生物循環液通過一定壓力輸送至塔體內。循環液通過耐酸的磁力耦合離心泵輸送,可以不間斷運行,並且與流量監控的限位開關相連,液體流量計持續監測,當流量過低,流量計中的錐形浮體便會下降至低位限位開關,並連鎖停止循環泵。若要重新激活循環泵,控製液體流量在低低液位以上。一般設計計時器的延遲時間為10秒鍾,以便於正常啟動(啟動時液體流量低)。
    In order to achieve the designed desulfurization target, the microbial circulating liquid is transmitted to the tower body under a certain pressure. The circulating liquid is delivered by the acid resistant magnetic coupling centrifugal pump, which can operate without interruption and is connected with the limit switch for flow monitoring. The liquid flowmeter continuously monitors. When the flow is too low, the conical floating body in the flowmeter will drop to the low limit switch and interlock to stop the circulating pump. To reactivate the circulating pump, control the liquid flow above the low low liquid level. Generally, the timer is designed with a delay time of 10 seconds for normal startup (low liquid flow at startup).
    如果循環泵在運行過程中出現故障,那麽故障信號將會傳送至控製櫃,控製麵板將指示相應的故障燈。此時,需操作人員在現場排查故障原因,通過重置循環泵以核實故障信息,可以嚐試將開關重置為“0”位,隨後將開關切換至“1”,使泵正常運行。通過此方法可檢測泵的吸入壓力及壓力管內部是否堵塞。
    If the circulating pump fails during operation, the fault signal will be sent to the control cabinet, and the control panel will indicate the corresponding fault light. At this time, the operator is required to find out the cause of the fault on the site, and verify the fault information by resetting the circulating pump. You can try to reset the switch to "0" position, and then switch the switch to "1" to make the pump operate normally. This method can detect the suction pressure of the pump and whether the inside of the pressure pipe is blocked.
    在循環液管道係統中,蝶閥、止回閥 、過濾器已經預裝在管線中,通過上述閥門可以用於關閉循環管路或調節循環泵壓力。
    In the circulating liquid pipeline system, the butterfly valve, check valve and filter have been pre installed in the pipeline. The above valves can be used to close the circulating pipeline or regulate the pressure of the circulating pump.
    特別注意:在啟動階段,循環泵之前的濾網每天清洗1-2次(主要原因是調試初期,塔體內可能存在一些雜質,例如設備生產時產生的一些pp碎片等)。經驗表明,調試期完成後,一般隻需要每周清洗1次,或每周檢查一次。
    Special attention: in the start-up phase, the filter screen before the circulating pump is cleaned 1-2 times a day (mainly because there may be some impurities in the tower body at the initial stage of commissioning, such as some pp fragments generated during equipment production). Experience shows that after the completion of the commissioning period, it is generally only necessary to clean once a week or check once a week.
    蜜桃视频中文字幕中的硫化氫先被吸附溶解,然後轉化為液相。硫化氫是以硫氫根離子形態懸浮溶解於液相,這種形態能被微生物氧化吸收。
    Hydrogen sulfide in biogas is first adsorbed and dissolved, and then converted into liquid phase. Hydrogen sulfide is suspended and dissolved in the liquid phase in the form of hydrogen sulfide ions, which can be oxidized and absorbed by microorganisms.
    為衝刷反應生成的硫磺,防止係統堵塞,需安裝耐酸的反衝洗泵。反衝洗泵設計為間歇運行,與流量控製器連鎖控製。當需要衝洗循環液時,該反衝洗泵由時間計電器激活後,即可以定時反衝洗。
    In order to flush the sulfur generated by the reaction and prevent the system from blocking, acid resistant backwash pump shall be installed. The backwash pump is designed to operate intermittently and interlocked with the flow controller. When it is necessary to wash circulating liquid, the backwash pump can be regularly backwashed after being activated by the time meter.
    與循環泵類似,反衝洗泵的液體流量計可持續監測循環液流量。如果流量過低,流量計中的錐形浮體便會下降至低限位開關,此時,反衝洗泵停止運行。若要重新讓反衝洗泵工作,控製液體流量在低低液位以上。一般設置計時器的延遲時間為10秒鍾,以便於正常啟動(啟動時液體流量低)。
    Similar to the circulating pump, the liquid flowmeter of the backwash pump can continuously monitor the circulating liquid flow. If the flow is too low, the conical floating body in the flowmeter will drop to the low limit switch, at this time, the backwash pump will stop running. To make the backwash pump work again, control the liquid flow above the low low liquid level. Generally, the delay time of the timer is set to 10 seconds for normal startup (low liquid flow during startup).
    如果反衝洗泵在運行過程中出現故障,那麽故障信號將會傳送至控製櫃,控製麵板上的相應的信號指示燈會亮起。此時,需現場排除故障原因,信號指示燈可以通過重置循環泵的開關進行確認,即將泵開關撥至“0”。隨後將泵開關撥至“1”,使泵繼續正常運行。通過此方法便可監測泵的吸入壓力及壓力管內部是否堵塞。蝶閥、止回閥、過濾器等,可用於切斷循環管路或調節壓力或保護循環泵不被汙染物堵塞。
    If the backwash pump fails during operation, the fault signal will be sent to the control cabinet, and the corresponding signal indicator on the control panel will light up. At this time, it is necessary to eliminate the cause of the fault on site. The signal indicator can be confirmed by resetting the switch of the circulating pump, that is, turning the pump switch to "0". Then, turn the pump switch to "1" to keep the pump running normally. This method can monitor the suction pressure of the pump and whether the inside of the pressure pipe is blocked. Butterfly valves, check valves, filters, etc. can be used to cut off the circulating pipeline or regulate the pressure or protect the circulating pump from being blocked by pollutants.
    特別注意:在啟動階段,反衝洗泵前端的濾網,每天清洗1-2次(主要原因是調試初期塔體內可能存在有一些雜質,包括設備生產時產生的一些PP-H碎片等)。經驗表明,調試期過後,一般隻需要每周清洗1-2次,或每周檢查一次。
    Special attention: in the start-up stage, the filter screen at the front end of the backwash pump is cleaned 1-2 times a day (mainly because there may be some impurities in the tower body at the initial stage of commissioning, including some PP-H fragments generated during equipment production). Experience shows that after the commissioning period, it is generally only necessary to clean 1-2 times a week, or check once a week.
    空氣供應量的設計,通過設置變頻器的參數,可以調整佳的空氣供應量。變頻器的預設值,通常可以實現佳的空氣鼓入量。生物脫硫係統的運行參數(pH、溫度)以及其他重要參數,可以傳輸至遠端控製係統。當然,通過對出口處硫化氫濃度的監測,可以連鎖控製關閉或啟動蜜桃视频中文字幕鍋爐或發電機:即當蜜桃视频中文字幕中的硫化氫濃度超過200-250ppm時,蜜桃视频中文字幕不再進入鍋爐或發電機組,而是改為火炬燃燒,以避免損壞發電機組。當硫化氫濃度低於200ppm時,發電機組可以正常投入運行,類似的功能,可以由用戶自行編程實現。
    The design of air supply can adjust the good air supply by setting the parameters of the inverter. The preset value of the frequency converter can usually achieve good air blowing. The operating parameters (pH, temperature) and other important parameters of the biological desulfurization system can be transmitted to the remote control system. Of course, through the monitoring of the hydrogen sulfide concentration at the outlet, the biogas boiler or generator can be closed or started under interlocking control: that is, when the hydrogen sulfide concentration in the biogas exceeds 200-250ppm, the biogas will no longer enter the boiler or generator set, but will be burned by torch to avoid damaging the generator set. When the concentration of hydrogen sulfide is lower than 200ppm, the generator set can be put into normal operation. Similar functions can be programmed by the user.

    相關產品 蜜桃免费在线视频的存在,是為了更好的服務於蜜桃视频中文字幕等可燃氣體淨化及利用行業
    網站地圖蜜桃视频入口网址 蜜桃AV网站免费看 蜜桃在线播放私人视频 樱桃视频污下载 蕾丝视频APP黄 榴莲视频WWW网站下载 99热在线观看 小黄鸭下载视频